  6.  
  7. 1.Proposed revisions to Recommendation N.1
  8.  
  9.          DEFINITIONS FOR APPLICATION TO INTERNATIONAL 
  10.                  SOUND-PROGRAMME TRANSMISSIONS
  11.                                 
  12.                                 
  13.        Add at the beginning of Recommendation N.1, an additional  reference  2)
  14. to the title of the Recommendation which refers to the following footnote:
  15.  
  16. "2.  Annex A to this Recommendation gives definitions for units of measurements 
  17.      for sound-programme transmissions".
  18.  
  19.        Add the following new annex to Recommendation N.1:  
  20.                                        
  21.                                   "ANNEX A*
  22.  
  23.                            (to Recommendation N.1)
  24.  
  25.                 Level and loss units used for sound-programme
  26.                          and television transmission
  27.  
  28.  
  29. 1.     Use of dB units in N Recommendations
  30.  
  31.        This Recommendation gives the quantities and units  for  sound-programme
  32. transmissions used in N Recommendations and are  in  accordance  with  existing
  33. Recommendations [1], [2].
  34.  
  35. 2.     Units used
  36.  
  37. 2.1    Absolute power level: dBm
  38.  
  39.        As a general rule, the dBm unit applies to the absolute power level. The 
  40. unit is based on the ratio between measured power and the reference power of  1
  41. mW.
  42.  
  43.  
  44.  
  45.  
  46.  
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53.  
  54.  
  55.  
  56.  
  57.  
  58.  
  59. ──────
  60.  
  61. * It is intended that the text contained in this annex will be further  studied
  62.   and refined as necessary. 
  63.        Absolute voltage levels, for which terminal impedance  is  not  defined,
  64. are more rarely used. As a  correction,  power  level  may  be  calculated  for
  65. impedances other than 600 ohms, with respect to 1 mW.
  66.  
  67.        The power level thus calculated would be equal to  that  measured  in  a
  68.  
  69.  
  70.  
  71.  
  72.  
  73.  
  74.  
  75.  
  76.  
  77.  
  78.  
  79. correctly terminated system.
  80.  
  81. 2.2    Relative level dBr
  82.  
  83.        The relative power level of a point in  a  transmission  system  is  the
  84. nominal power gain at the reference frequency from a reference point to the point 
  85. considered. The same consideration is used for the relative voltage level in  a
  86. transmission system based on voltage levels.
  87.  
  88.        Relative levels can be used to compare two or more points of  a  network
  89. with respect to power (or voltage). One point of a network is usually defined as 
  90. the reference point at 0 dBr, from which other measurement points are derived.
  91.  
  92.        For sound-programme circuits, the zero relative level is located at  the
  93. injection point, i.e. usually at the transmission point  of  a  sound-programme
  94. circuit.
  95.  
  96. 2.3    Absolute zero power level dBmO (load level*)
  97.  
  98.        In a transmission system based on power levels the absolute power  level
  99. or load level (Lmo) with respect to 1 mW is referred to a point of zero relative 
  100. level. That means that the absolute power level (Lm) minus the  relative  power
  101. level (Lr) will be
  102.  
  103.        LmO = Lm - Lr 
  104.  
  105.        This level indication is independent of the relative power level at  the
  106. measurement point considered. For a given signal the load level is nominally the 
  107. same along a transmission line. For this indication it is necessary to know  to
  108. what extent the power at the zero relative point is greater or  less  than  the
  109. reference power.
  110.  
  111. 2.4    Relation between quantities and units
  112.  
  113.        There is a fixed relation between level quantities and units, namely:
  114.  
  115. Absolute power level = relative power level +
  116.                        absolute zero power level (load level)
  117.  
  118.        Lm = Lr + LmO
  119.  
  120. Therefore, for the level units: a dBm = b dBr + c dBmO.
  121.  
  122.        When indications are given concerning the line signal, the absolute zero 
  123. power level (load level) (dBmO) is given, at which, at the relative zero point, 
  124. the absolute power level coincides with the relative power level.
  125.  
  126.        Lm = LmO  │
  127.                    │  Lr = O
  128.  
  129.           
  130.  
  131. *  The term "load level" is  used  provisionally  and  is  subject  to  further
  132.    consideration.
  133.  
  134.        In order to simplify the specification of the level of a  circuit  or  a
  135. system it is most appropriate to specify the absolute power level which coincides 
  136. with the relative zero power level. Thus this  absolute  power  level  and  the
  137. absolute zero power level (load level) are the same.
  138.  
  139. 2.5    Weighted level
  140.  
  141.  
  142.  
  143.  
  144.  
  145.  
  146.  
  147.        Power level of disturbing signals are as a rule expressed  in  the  same
  148. units as those defined above. For noise measurements made by a weighting filter, 
  149. (psophometric measurements), a "p" (for "pondéré" = weighted) is added  to  the
  150. units, e.g.: dbmOp, dBmp.
  151.  
  152.        A "q" indicates a quasi-peak value where the "m" is replaced  by  a  "q"
  153. which, for instance, in dBm gives dBq.
  154.  
  155. 2.6    Extra indications
  156.  
  157.        Sound-programme transmission level units are indicated by an  extra  "s"
  158. (s for sound), dBrs, dBmOs, dBmOps, dBqOpS.
  159.  
  160.        Extra indications for units should  be  used  whenever  they  facilitate
  161. understanding so as to prevent confusion when differing measurement techniques, 
  162. weighting filters or meters are used.
  163.  
  164. 3.     Various measuring instruments
  165.  
  166.        Absolute power level (in dBm) is obtained if a measurement is made on  a
  167. terminated line.
  168.  
  169.        Various measuring instruments provide measurements related to a (freely) 
  170. preselected relative level value. The measurement will  then  directly  express
  171. the absolute zero power level (load level).
  172.  
  173. 4.     Practical problems
  174.  
  175.        There is a  wide  range  of  measuring  instruments  used  at  different
  176. measurement points, so that differences are always bound to appear. A state which every 
  177. administration is prepared to define is  the  permitted  maximum  level  (PML).
  178. Despite different relative power levels, depending on the systems, a direct relation 
  179. can now be indicated between the value of the level to be measured and the  PML
  180. in dB. If, for instance, a signal of 21 dB below the PML is  transmitted  as  a
  181. measurement signal, it must also be received as  a  signal  21  dB  below  PML,
  182. independently of local relative levels, which may differ according to systems and 
  183. administrations.
  184.  
  185. REFERENCES
  186.  
  187. [1]  CCITT  Recommendation  B.12   "Use   of   the   decibel   and   neper   in
  188.     telecommunications".